Fire Resistance Performance

Mayplas FR Reveal Cavity Closer has been independently tested in accordance with BS EN 1366-4:2021 and classified in accordance with BS EN 13501-2:2023

Integrity (E)
(Vertically and horizontally)
Insulation (I)
(Vertical)
Insulation (I)
(Horizontal
120 mins60 mins15 mins

FR Reveal Cavity Closer


The Mayplas FR Reveal Cavity Closer has been designed to close cavities for fire, thermal and acoustic purposes; it reduces cold bridging when closing cavities at door and window frames.

Call 0161 447 8320

CONTACT FORM

DOWNLOAD TECHNICAL DATA SHEET

PRODUCT

Mayplas FR Reveal Cavity Closer consists of a strip of engineered Stone Mineral Wool insulation laminated to a Polythene DPC. It is produced in a range of sizes to fit cavity widths up to 100mm within masonry systems.

FEATURES and BENEFITS

Mayplas FR Reveal Cavity Closer consists of a strip of engineered Stone Mineral Wool insulation laminated to a Polythene DPC. It is produced in a range of sizes to fit cavity widths up to 100mm within masonry systems.

FeatureBenefits
Closes cavities up to 100mm wideReduces cold bridging when closing cavities at door and window frames
Provides integrity and insulation against the passage of fireHelps ensure that openings in cavity walls do not encourage the spread of fire into or out of the cavity. Suitable for vertical and horizontal applications.

TECHNICAL PROPERTIES


Dimension of finished product100mm wide, 1200mm long with a black DPC
overlapping 40mm either side of the barrier
DPCThe DPC is 1300mm long which allows a 100mm overlap with the next closer. The overlap is located at the bottom of each closer to ensure that any moisture remains on the face of the DPC which prevents the ingress of moisture into the stone mineral wool strip. The DPC conforms to BS 6515.
Width of cavity (for barriersFrom 25 to 100mm cavities
Thermal Conductivity (W/mK)0.035 W/mK
Management SystemsCertified as meeting the requirements of
ISO 9001, ISO 14001, ISO 45001